Chapter 2. CLI Syntax Reference121 3ware SAS/SATA RAID Controller CLI Guide, Version 9.5.2/cx/bbu show tempThis command shows the temperature status of the battery. The status can beOK, HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and LOW are inwarning range. TOO-HIGH and TOO-LOW are out of the operating rangeand indicate that it may be time to replace the battery. (Contact LSI to obtain areplacement battery.)/cx/bbu show voltThis command shows the voltage status of the battery. The status can be OK,HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and LOW are inwarning range. TOO-HIGH and TOO-LOW are out of the operating rangeand indicate that it is time to replace the battery. (Contact LSI to obtain areplacement battery.)/cx/bbu show allThis command shows the current settings of all BBU-related attributes: ready,status, batinst, lasttest, volt, temp, cap, serial, fw, pcb, bootloader.Example://localhost> /c1/bbu show all/c1/bbu Firmware Version = BBU: 2.00.00.023/c1/bbu Serial Number = L319003B7460719/c1/bbu BBU Ready = Yes/c1/bbu BBU Status = OK/c1/bbu Battery Voltage = OK/c1/bbu Battery Temperature = OK/c1/bbu Estimated Backup Capacity = 241 Hours/c1/bbu Last Capacity Test = 22-Jun-2008/c1/bbu Battery Installation Date = 20-Jun-2008/c1/bbu Bootloader Version = BBU 0.02.00.002/c1/bbu PCB Revision = 65//localhost>