Controller Object Commandswww.3ware.com 76Example://localhost> /c1 set verifyrate=2Setting Verify background task rate on /c1 to [2] (faster I/O) ... Done.Related commands:/cx show verifyrate/cx set verifymode=/cx show verifymode/cx set selftest=enable|disable[task=UDMA|SMART]This command enables or disables all selftest tasks or a particularselftest_task (UDMA or SMART).The selftest schedule is always enabled.For 3ware RAID controllers older than the 9690SA, two self-tests can be set:one to check whether UDMA Mode can be upgraded (applies to PATA drivesonly) , and another to check whether SMART thresholds have been exceeded.For the 9690SA, you can only check the SMART thresholds for drives.7000/8000 series have the same internal schedule, but it is not viewable orchangeable.Example://localhost> /c0 selftest=enable task=UDMAenables UDMA selftest on controller c0./cx set exportjbod=on|offThe JBOD Export Policy is only supported on 9000-series controllers.Previous models did not have such a policy enforcement feature.This command allows you to set the JBOD Export Policy to on or off. Bydefault, exportjbod is off.If the JBOD export policy is off, CLI will not be able to create JBODs. Duringreboot, firmware will not export JBOD units to the operating system.A JBOD is an unconfigured disk attached to your 3ware RAID controller. LSIrecommends that you use Single Disk as a replacement for JBOD, to takeadvantage of features such as RAID level migration.Note: SAS drives cannot be JBODs.
PreviousNext |