Controller Object Commandswww.3ware.com 48p14 NOT-PRESENT - - - -p15 NOT-PRESENT - - - -Name OnlineState BBUReady Status Volt Temp Hours LastCapTest---------------------------------------------------------------------------bbu On Yes OK OK OK 0 xx-xxx-xxxx/cx show alarms [reverse]Asynchronous event notifications (also referred to as AENs or controlleralarms) are originated by controller firmware or an SES attached enclosure(9690SA or 9650SE only) and captured by the 3ware device drivers. Theseevents reflect warnings, errors, and/or informative messages. These events arekept in a finite queue inside the kernel, and can be listed by CLI and 3DM 2.They are also stored in the operating system events log.The /cx show alarms command displays all available events on a givencontroller. The default is to display the events in ascending order—that is, theoldest event messages appear at the top, and the most recent event messagesappear at the bottom. You can use the [reverse] attribute to display the mostrecent event message at the top.Events generated on 7000/8000 series controllers do not have dates, so youwill see a '-' in the Date column. This means that it is not applicable. Inaddition, alarm messages on 7000/8000 controllers contain the severity in themessage text, so the Severity column also shows a '-'.Example: Typical output looks like://localhost> /c1 show alarmsCtl Date Severity AEN Message---------------------------------------------------------------------------c0 [Fri Mar 21 2008 14:19:00] WARNING Drive removed: port=1c0 [Fri Mar 21 2008 14:19:00] ERROR Degraded unit: unit=1, port=1c0 [Fri Mar 21 2008 14:19:25] INFO Drive inserted: port=1c0 [Fri Mar 21 2008 14:19:25] INFO Unit operational: unit=1c0 [Fri Mar 21 2008 14:28:18] INFO Migration started: unit=0c0 [Sat Mar 22 2008 05:16:49] INFO Migration completed: unit=0c0 [Tue Apr 01 2008 12:34:02] WARNING Drive removed: port=1c0 [Tue Apr 01 2008 12:34:22] ERROR Unit inoperable: unit=1c0 [Tue Apr 01 2008 12:34:23] INFO Drive inserted: port=1c0 [Tue Apr 01 2008 12:34:23] INFO Unit operational: unit=1/cx show events [reverse]This command is the same as “/cx show alarms [reverse]”. See details above.