Menu Descriptions61179641L4-5B 5-45Inband OAM Loopback Test MenuInband OAM Loopback TestMain Menu\ATM Circuit Management\ATM OAM Settings\Inband OAM Loopback Test\The Inband OAM Loopback Test menu (see Figure 5-27) is used to provision the Total Access1248 OAM Loopback settings and to test the Inband channel PVC for an ATM fed box.Figure 5-27. Inband OAM Loopback Test MenuThe Inband OAM Loopback Test menu options are shown in Table 5-26.The Inband OAM Loopback Test menu fields are shown in Table 5-27.Table 5-26. Inband OAM Loopback Test Menu OptionsOption Description Function1 Remote OAM LoopbackLocation IDThis is option is used to enter the remote loopbacklocation ID. The remote loopback location ID is inhexadecimal 16 byte format.2 Type of OAM Loopback Cell This option is used to specify the type of OAM Loopbackcell. Options include the following:• Segment• End-to-End3 Send Loopback Cell This option is used to send a loopback cell.4 Reset Loopback Statistics This option clears the OAM loopback statistics for thiscircuit.5 Reset All Statistics This option clears all OAM loopback statistics.TID: TA1248 Total Access 1248Unacknowledged Alarms: NoneInband OAM Loopback TestPort VPI VCI0 0 32Tx Loopback Request : 0 Rx OAM Cells : 0Rx Loopback Request : 0 AIS State : FALSETx Loopback Response : 0 RDI State : FALSERx Loopback Response : 0Loopback Passed : 0Loopback Failed : 01. Remote OAM Loopback Location ID : FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF2. Type of OAM Loopback Cell : Segment3. Send Loopback Cell4. Reset Loopback Statistics5. Reset All StatisticsSelection :'?' - System Help Screen