4-7RAIDUTIL Command Line UtilityRAID Operation-C Load/save configurationThis switch has two options:A file name must follow the load or save parameter. This is a .dsmfile, which can also be loaded or saved using Storage Manager.-r Specify task rateThis switch sets a task priority for the device or logical drive. Theparameter can be 0 – 9; with 0 being the slowest and 9 being thefastest. You can also specify the rate as follows:The device address is required. Specify logical drives by their deviceaddresses. You can set the rate for all logical drives on a controller byusing the device address of the controller.-w Write cachingOptions are On and Off. The default (On) uses Write-Back caching.Off sets the operation to Write-Through caching. Specify drivesusing the device address.load Loads the specified configuration filesave Saves the current configuration to the file namespecified-r slow = 1-r medslow = 3-r med = 5-r medfast = 7-r fast = 9