2-25Storage Manager on ROMThe Status section displays the current status of the array. Aprogress indicator (a numeric percentage of completion) can alsoappear if the array is building or rebuilding. The status definitionsare listed below:SCSI only—The SCSI Capabilities section is a list of controllercapabilities. A check mark next to a feature indicates that the drivesupports the feature.Setting the ConfigurationThere are two configuration options on the File menu: Read System Config—Causes SMOR to rescan to detect anychanges in hardware configuration or status. Any changes thathave been made and not saved are lost. This operation is runautomatically when SMOR is started. Set System Config—Causes SMOR to save changes that havebeen made to the storage subsystem configuration in thecontroller memory. If any array groups or multilevel RAIDshave been created or modified, this operation causes thecontroller to initiate a build operation on the new groups.Building The array is being built.Created The array or device is defined, but not initialized.Dead A Write Back Cache command to the array failed. Thisis an unrecoverable failure.Degraded A single drive in the array failed; array performance isdegraded.Impacted A verification is being performed on the array; I/Operformance is affected.Optimal The array is fully functional.Pending The array has been created and the build is queued onthe controller, but not yet started.Rebuilding Data is being rebuilt onto a drive in the array.