www.baldormotion.comSpecifications 8-23MN19438.3.11 Motor output rating adjustment - 26 A modelThe continuous current rating of the MotiFlex e100 is affected by the chosen overload type andswitching frequency, as shown in Table 27. These settings can be selected in the MintWorkBench Drive Setup Wizard - see the Mint help file for details.Servo motor Induction motor LowspeedStationary:DC output300%, 3 soverload200%, 3 soverload150%, 60 soverload110%, 60 soverloadspeedoutput(< 2 Hz)DC output(any phase)4 kHz 20 A 29 A 29 A 29 A 25 A* 42 A (DC)8 kHz 19 A 26 A 26 A 26 A 22 A* 32 A (DC)16 kHz 12.5 A 12.5 A 12.5 A 12.5 A 8 A* 14 A (DC)* Estimated valuesTable 27 - Continuous current ratings for 26 A modelThe continuous current ratings shown in Table 27 must be derated if the drive is operating in anambient temperature between 45 °C (113 °F) and the absolute maximum operating temperatureof 55 °C (131 °F):4 kHz8 kHz16 kHz45 4746 48 49 50 51 52 53 54 55 56Ambient temperature (ºC)Derated output(% of continuous current rating)4450556065707580859095100Figure 91 - Temperature derating for 26 A modelWhen sharing the DC bus, it becomes critical to consider the overall power beingderived from the drive’s internal power supply. See section 8.2.3.CAUTION