Condition TEACH Result DisplayOne valid TEACH point that, afteroffset, becomes invalid Sets a switch point at the following location:Model Switch Point100 mm threaded barrel models 75300 mm threaded barrel models 200600 mm threaded barrel models 400110 mm flush mount models 85310 mm flush mount models 210610 mm flush mount models 410and the switch point distanceflash alternately on the display.3.6.5 Dual (Intensity + Distance)Dual (intensity + distance) TEACH records the distance and amount of light received from the reference surface. The outputswitches when an object passing between the sensor and the reference surface changes the perceived distance or amount ofreturned light. For more information on dual TEACH mode, see Dual (Intensity + Distance) Mode on page 36.Note: To use the following instructions, set the sensor to = . The DYN, FGS, and BGS indicators areamber.Note: To program the sensor using remote input, remote input must be enabled ( = ).2Press and Hold> 2s13Press againIncreasedHeightand/orIntensityDecreasedHeightand/orIntensityReferenceSurface1. Present the target.Method Action ResultPush ButtonRemote Input Present the reference target. The target's match percentage displays2. Start the TEACH mode.Q4X Stainless Steel Laser Sensor with Dual Discrete Outputs and IO-Linkwww.bannerengineering.com - Tel: 763.544.3164 27