2.8.2 Safety and Warning ZonesThe software makes it easy to establish Safety and Warning Zones. The Safety Zone and the Warning Zone are user-defined areas that the Scanner monitors. An intrusion into the Safety Zone (such as a person walking into a monitored workcell) causes the SX5 to turn its safety outputs off. An intrusion into the Warning Zone causes the SX5 to create a warningsignal.Safety Zone and Warning Zone settings are created and saved as zone sets. Up to 6 configurable zone sets are availablefor the SX5. Zone sets can be enabled or disabled, one set at a time, while the SX5 is operational and actively monitoring awork area. This function is useful when changing machine guarding requirements create the need for changes in SafetyZone and Warning Zone dimensions.2.8.3 Monitored Space DisplayWhen the SX5 is actively monitoring an area, it measures the distance to, and the angular position of, objects in the area.These measurement data are transferred via an Ethernet connection to the PC when the Monitoring function is selected.The software uses this data to constantly update the display to show the Safety Zone and Warning Zone along with themeasured surfaces of the monitored area.Figure 12. Monitored space as shown by the SX5soft software2.9 Security ProtocolCertain procedures for installing, maintaining, and operating the SX5 must be performed by either Designated Persons orQualified Persons.A Designated Person is identified and designated in writing, by the employer, as being appropriately trained and qualified toperform system resets and the specified checkout procedures on the SX5. The Designated Person is empowered to:• Perform manual resets and hold possession of the reset key• Perform the Daily Checkout ProcedureA Qualified Person, by possession of a recognized degree or certificate of professional training, or by extensive knowledge,training, and experience, has successfully demonstrated the ability to solve problems relating to the installation of the SX5System and its integration with the guarded machine. In addition to everything for which the Designated Person isempowered, the Qualified Person is empowered to:• Install the SX5 System• Perform all checkout procedures• Make changes to the internal configuration settings• Reset the System following a Lockout condition2.10 General Safety Information• The machine stopping system must be electrically controlled.• This control system must be capable of stopping the dangerous movement of the machine within the total machinestopping time (Ts) and during all the machine cycle phases.SX5 Safety Laser Scannerwww.bannerengineering.com - Tel: +1.763.544.3164 19