ConfigurationAcceptedConfiguration NotAccepted Name DescriptionSafety Zone Signal The device is correctly functioning. The device has detected an objectin the Safety Zone.Reference Point Signal Reference points have moved. The display sector in the direction ofthe moved point is shown in blue.9.4 Diagnostic Notes, Warnings, and ErrorsIcon Fault Code Device Status OSSD Status DescriptionDLDNF Normal Off Downloading the new firmware.DLDNC Normal Off Downloading the new configuration.CLEANW2 Normal On Clean the window to avoid a lockout condition.ITLOCK1 Normal Off Interlock; waiting for a restart signal to turn the OSSDs back on.INTF6 Normal OnNon-safety related internal test failure.Reset the system using the reset function or cycle the power to thedevice.If the failure persists, contact the factory for support.EXTTEMP Normal OnThe device is operating in an environment that exceeds the specifiedoperating temperature range. Restore the correct ambient temperatureconditions.BOOTF Normal Off Invalid boot. Re-boot the system until the normal condition is restored.If warning persists, contact the factory for support.SX5 Safety Laser Scannerwww.bannerengineering.com - Tel: +1.763.544.3164 83