Safety DataType 3 (EN 61496-1)SIL 2 (IEC 61508)Category 3 (EN ISO 13849-1)SILCL 2 (EN 62061)PL d (EN ISO 13849-1)PFHd (mean probability of a dangerous failure per hour): 6.38 × 10-8SFF: 97.58%MTTFd: 61 YearsTM (mission time): 20 years (EN ISO 13849-1)HFT (Hardware Fault Tolerance): 1State of safety: OSSD in OFF State (open circuit → I OSSD = 0)Response time to malfunction: ≤ Response TimeOperating Conditions0 °C to +50 °C (+32 °F to +122 °F)795% maximum relative humidity (non-condensing) (According to IEC61496-1 5.4.2; IEC 61496-3 5.4.2; 4.3.1; 5.4.4.3)Storage Conditions–20 °C to +70 °C (–4 °F to +158 °F)Environmental RatingIEC IP65FeaturesSafety protective field range: 3 m, 5.5 mWarning field range: 40 m with remission of target = 90% (white)Scanning angle: 275°Detection capability: 40 mm, 70 mmScan cycle time: 30 msResponse time: Programmable 62 to 482 msTolerance zone max: 150 mmAngular resolution: 0.1°Zones sets: 6 MaxVibrationAccording to IEC 61496-1 4.3.3.1 ; 5.4.4.1 ; IEC 60068-2-6Frequency from 10 Hz to 55 Hz ; Scan Speed 1 octave/minRange: 0.35 mm ± 0.05 mmShockAccording to IEC 61496-1 4.3.3.2 ; 5.4.4.2IEC 60068-2-29; Acceleration: 10 g; Pulse Duration: 16 ms; Number ofShocks: 1000 ± 10 (for each of the three mutually perpendicular axes)IEC 61496-3 5.4.4.1-3 ; IEC 60068-2-75 ; Hammer test2.11.2 Dimensions7 We recommend that you allow for a 15-minute warmup from a cold start.SX5 Safety Laser Scannerwww.bannerengineering.com - Tel: +1.763.544.3164 21