Important:In addition to the level of airborne particles in the scanner's environment, some special lighting conditionsalso affect the detection sensitivity. These conditions are:• high reflective backgrounds within 3 meters of the Safety Zone boundary• the presence of bright light within +/- 5 ° of the detection plane.Include an additional distance in the Minimum Safety Distance calculations for these cases. See thegraphs in the SX5's instruction Manual for these additional distances.Click on the white > arrow in the upper right corner to move to the next configuration screen. Click on the white < to returnto the previous screen.6.5.5 Create or Edit Safety and Warning ZonesFigure 52. Zone Configuration screenTools are provided to draw the Safety and Warning Zones. It is possible to select different shapes and different functions tomanage the graphing.• On the right are the various configuration icons.• On the left are a list of the various zones that can be configured.• In the center is the area graph. The center of the scanner is the point where the two axes intersect.1. In the left panel, click on the zone name to edit. Do not select the zone checkbox. The zone must be highlighted tobe edited or displayed. If no zone is highlighted, Zone 1 - Safety is being created. To modify an existing zone, right-click on the zone name.SX5 Safety Laser Scanner70 www.bannerengineering.com - Tel: +1.763.544.3164