90˚Figure 34. Adjust the scanner angleTo mount the device with 90° vertical inclination:1. Mount the Positioning Memory Bracket (3) with the M4 screw (and washer) (2) to the main bracket (1) but do nottighten it.2. Align the Positioning Memory Bracket with the center of the main bracket slot, then tighten the M4 screw (do notexceed 1.5 to 2 N·m torque).3. Mount the scanner to the main bracket using the M5 × 12 Pitch Adjustment Screws (with washers) (5) and the M5 ×12 Scanner Fastening Screws (4). Tighten all four screws (do not exceed 2.5 to 3 N·m torque).To place a device with a specific pitch angle:1. Screw without tightening the M5 Scanner Fastening Screws, the M5 Pitch Adjusting Screws, and the PositioningMemory Bracket with the M4 screw.2. Rotate the device to the desired pitch angle within the allowed range (± 6°).3. Tighten the M5 Scanner Fastening Screws and then the M5 Pitch Adjusting Screws (do not exceed 2.5 to 3 N·mtorque).4. Tighten the Positioning Memory Bracket M4 screw (do not exceed 1.5 to 2 N·m torque).3.10.5 Adjusting the Roll AngleThe roll angle adjustment procedure only applies when all parts of bracket SXA-MBK-1 are used.Rotate the brackets to reach the desired roll angle within the allowed range (± 8.5°). Tighten the M4 Roll Adjusting Screws(7) (do not exceed 1.5 to 2 N·m torque) .8.5°Figure 35. Adjust the roll angle3.10.6 Scanner Mounting Safety InformationVerify the protection level assured by the SX5 Safety Laser Scanner is compatible with the danger level of the workingmachine, according to EN ISO 13849-1 or EN 62061.Dangerous Machine Status:• Verify the machine is off (not operating) during mounting, electrical installation, and commissioning.• Verify the safety laser scanner’s outputs do not affect the machine during mounting, electrical installation, andcommissioning.SX5 Safety Laser Scannerwww.bannerengineering.com - Tel: +1.763.544.3164 39