Figure 236. Show Measure Tool Annotations Figure 237. Hide Measure Tool AnnotationsInspection Pass/FailSelect the Contribute to Inspection Pass/Fail check box (default) if the tool will influence the Pass/Fail status of theinspection.Figure 238. Inspection Pass/FailThe Pass/Fail contribution influences the following:• Discrete output Pass• Discrete output Fail• Pass/Fail results counter• Pass (Green) and Fail (red) LEDs on the SensorSelect this checkbox if the overall Pass/Fail status of the inspection is dependent on the current tool.9.2.3 Measure Tool: Test ParametersUse the Test parameters to configure the pass/fail conditions for the tool.Select the parameter checkbox to enable it. Where applicable, the vertical green bar shows the current parameterinformation and the light gray backgrounds show the range over which a value has varied over time.Figure 239. Measure Tool—Test ParametersDistanceThe straight-line distance between two constants ortools.Distance XThe x dimension vector component of the straightline distance.Distance YThe y dimension vector component of the straightline distance.AngleThe angle with respect to the x axis, along which thestraight line measurement vector lies. If the tool ismeasuring from one Line tool to another Line tool,the Angle is the measurement of the angle formedby the two lines. If the Force to Absolute parameteris selected, the angle is calculated relative to thereference tool that precedes the Measure tool.9.2.4 Measure Tool: ResultsTools & Results and All Results list information from the current and previous inspections.A red box around a tool indicates that the tool failed. Status provides information about the specific failure.All Results displays the Result, Time, Pass Count, and Fail Count information at a glance. Expand the inspection tool tosee specific results for that tool.VE Series Smart Camera122 www.bannerengineering.com - Tel: 763.544.3164