OffsetThe offset between the Edge Point and the reference point.Expand Offset to see the coordinates of the Reference Point, the Reference Angle, the Offset Point, and the OffsetAngle.Maximum Edge StrengthThe greatest rate of change value observed by the tool.Available when the Threshold Type is set to Edge Strength.Execution TimeThe execution time, in milliseconds, for the currently selected tool in the current inspection.Expand Execution Time to see the historical minimum and maximum execution times up to this point for theselected tool.Use the reset button in the Inspection Summary to reset these historical values.StatusStatus and error messages display as appropriate.8.6.4 Using the Locate ToolFollow these steps for an example Locate inspection to adjust for a target that moves in the field of view, allowing for theprecise placement of the vision tools that follow the Locate tool.This procedure uses a Locate tool to determine the position of the vial. Using the vial position information, three Edge toolsand two Measure tools determine the position of the stopper. The Locate tool is used to ensure that the Edge02 andEdge03 tools are placed correctly alongside (but not on top of) the vial, even if the vial targets move from side to side inthe field of view from inspection to inspection. See Using the Edge and Measure Tools on page 86 for details on how to setup an Edge tool and a Measure tool.NOTE: This procedure is an example only.1. Add a Locate tool to the inspection.2. Adjust the ROI position, length, and width.a) Position the ROI horizontally across the side of the vial.b) Leave the ROI Width at the default (13 px).Figure 168. Locate ROIVE Series Smart Camerawww.bannerengineering.com - Tel: 763.544.3164 95