Network Settings: PROFINET (XS/SC26-2 FID 2 Only and SC10-2)After selecting the PROFINET protocol on the Industrial Ethernet tab, click Network Settings on the Software to open theNetwork Settings window.Figure 89. Network Settings—PROFINETClick Send to write the network settings to the Safety Controller. Network settings are sent separately from theconfiguration settings.Click Network Timeout Enabled to have all configured Virtual On/Off or Virtual Mute Enable become inactive in the event ofa network timeout condition. The network timeout time is fixed at 5 seconds.Note: Use Password Manager to enable or disable the ability for User2 and User3 to change the networksettings.9.8.2 EtherNet/IP Assembly ObjectsNote: The EDS file is available for download atwww.bannerengineering.com. An Ethernet User's Guide isavailable with the download.Input (T->O) Assembly ObjectsInstance ID Data Length (16-bit words) Description100 (0x64) 8 Used to access the basic information about the Virtual Status Outputs 1–64.101 (0x65) 104 Used to access the advanced information (including the basic information)about the Virtual Status Outputs.102 (0x66) 150 Used to access the fault log information and provides no Virtual StatusOutput information.103 (0x67) 35Used to access the basic information about Virtual Status Outputs 1–256and feedback information about Virtual Reset and Virtual Cancel Delayinputs. Available on FID 2 Base Controllers and SC10-2.Output (O->T) Assembly ObjectInstance ID Data Length (16-bit words) Description112 (0x70) 2 Reserved113 (0x71) 11 Used to control Virtual Inputs (On/Off, Mute Enable, Reset, Cancel Delay).Available on FID 2 Base Controllers and SC10-2.Configuration Assembly ObjectThe Configuration Assembly Object is not implemented. However, some EtherNet/IP clients require one. If this isthe case, use Instance ID 128 (0×80) with a data length of 0.Set the Data Type of the communication format to INT.Set the RPI (requested packet interval) to a minimum of 150.XS/SC26-2 and SC10-2 Safety Controllers104 www.bannerengineering.com - Tel: + 1 888 373 6767