System LockoutIndicates a Non-Operating Lockout Condition, for example unmapped input connected to 24 V.7.10 Virtual Status OutputsUp to 64 Virtual Status Outputs can be added for any configuration using Modbus/TCP, EtherNet/IP Input Assemblies,EtherNet/IP Explicit Messages, and PCCC protocols on FID 1 Base Controllers and up to 256 virtual Status Outputs can beadded on FID 2 Base Controllers and SC10-2 Safety Controllers. FID 2 Base Controllers and SC10-2 Safety Controllers canalso use PROFINET. These outputs can communicate the same information as the Status Outputs over the network. SeeStatus Output Functionality on page 60 for more information. The Auto Configure function, located on the IndustrialEthernet tab of the Software, automatically configures the Virtual Status Outputs to a set of commonly used functions,based on the current configuration. This function is best used after the configuration has been determined. Virtual StatusOutput configuration can be manually revised after the Auto Configure function has been used. The information availableover the network is consistent with the logical state of the inputs and outputs within 100 ms for the Virtual Status Outputtables (viewable via the Software) and within 1 second for the other tables. The logical state of inputs and outputs isdetermined after all internal debounce and testing is complete. SeeIndustrial Ethernet Tab on page 102 for details onconfiguring Virtual Status Outputs.XS/SC26-2 and SC10-2 Safety Controllerswww.bannerengineering.com - Tel: + 1 888 373 6767 61