The iVu Plus BCR RS232 port or ethernet port can be used to output barcode data to other applications. To access the Data Exportscreen, go to Main Menu > System > Communications > Data Export . The user can enable or disable this feature. When enabled:• if the sensor is configured for either External-Single or External-Gated trigger modes, every trigger results in the transmission of out-put data (if the sensor does not successfully read a barcode, the output will be NO_READ).• if the sensor is configured for Continuous trigger mode, the sensor will only transmit output barcode data upon a successful read.To access the Serial Output screen, go to Main Menu > System > Communications > Serial I/OWhen RS-232 serial output is enabled, the user can configure:• Serial Port Settings (listed below)• Type of Data to Export (listed below)• Output Format (listed below)To access the Ethernet Output screen, go to Main Menu > System > Communications > Ethernet I/O .When ethernet output is enabled, the user can configure:• IP Address, Port number, Subnet Mask, and Gateway• Type of Data to Export (listed below)• Output Format (listed below)Type of Data to Export:• Pass/Fail Output• Inspection Name• Barcode Count• Data Length• Symbol Type• Barcode Data• Frame Number• Inspection Time (ms)Serial Port Settings:• Baud Rates• Start Bits• Stop Bits• Data Bits• Parity ControlOutput Format:• Start String• Delimiter• End StringiVu Plus BCR User's ManualRev. B www.bannerengineering.com - tel: 763-544-3164 19