2 Installation2.1 Components2.1.1 iVu with Integrated DisplayThe iVu Series sensor comes fully assembled with the lens and an integrated ring light if so ordered. The integratedtouchscreen display has a plastic cover to protect the display. Remove this cover when setting up the sensor. When thedisplay is not in use be sure to keep the display covered to protect it.If an integrated ring light is not used, another light source is needed. Various lights are available from Banner. Operatingin external trigger mode requires a triggering source (for example, the Banner WORLD-BEAM® QS18VN6D sensor).1 LED - Green: Ready; Red: Error2 LED - Green: Pass; Red: Fail3 Ethernet I/O LED4 Focusing Window5 Focusing Window Locking Clip6 Integrated DisplayCA BA 8-pin Euro-style (M12) female USB Cable ConnectorB I/O Cable ConnectorC 12-pin Euro-style (M12) male Power and I/O Cable ConnectorMounting Bracket Mounting Holes (uses supplied three M4 x 4 mm screws)2.1.2 iVu with Remote DisplayThe iVu sensor for use with a Remote Display comes fully assembled with the lens and an integrated ring light if soordered. Although the Remote Display is not required for normal sensor operation, it is needed to set up the sensor and tomonitor inspections.If an integrated ring light is not used, another light source is needed. Various lights are available from Banner. Operatingin external trigger mode requires a triggering source (for example, the Banner WORLD-BEAM® QS18VN6D sensor).iVu Plus TG Gen2 Image Sensor6 www.bannerengineering.com - Tel: 763.544.3164