• Set the Pass Count parameter. The Minimum Pass Count is the minimum number of parts, labels, orfeatures expected to fall within the specified criteria; the Maximum Pass Count is the maximum numberexpected to fall within the specified criteria. These settings are used to determine the pass or fail result ofthe inspection.1. Set the Minimum Pass Count and Maximum Pass Count as appropriate. In the Demo, both areset to indicate the expected feature count is equal to 1. If the count is more than 1 or less than 1,the sensor will fail.6. Test the complete range of good and bad samples to make sure that the sensor accepts good parts and rejectsbad.7. To complete the Match application setup, set triggering as appropriate for the application.NOTE: When running a Match inspection, the sensor will look for any possible patterns to matchanywhere within the Field of View.7.4.1 Remote TeachThe Remote Teach function is a method of remotely updating inspection parameters while the iVu sensor is running.Remote Teach is only available when the iVu is configured as a Match sensor. The sequence of events for executing aRemote Teach are:1. With the sensor Ready (see Installation on page 6), pulse the Remote Teach line.2. The sensor recognizes that the Remote Teach line has been pulsed and waits for the next valid trigger.3. At the next valid trigger, Ready goes inactive (the Green Ready LED shuts OFF), and the sensor acquires a newimage.4. The sensor learns the new pattern and performs the analysis.iVu Plus TG Gen2 Image Sensor70 www.bannerengineering.com - Tel: 763.544.3164