7.5 Configuring a Sort ApplicationNOTE: By default, the Trigger is set to Internal, and will continuously trigger based on a time intervalsetting. This may make it more difficult to make adjustments while setting up the sensor. The bestpractice is as follows:• Go to the Main Menu > Imager > Trigger menu and select External.• Make sure there is no external trigger input.• Use the Trigger icon in the lower-right of the screen to manually trigger the sensor to capturean image as you set up and test.• Capture images of a range of samples to set up from the "worst" good part to the "best" badpart.1. Make sure you use good parts for the inspection setup. Normally, each part will be centered in the field of viewwith the feature of interest surrounded by the Region of Interest (ROI).For the first part, select the ROI by clicking inside it. Move it, resize it, and rotate it by dragging the ROI or itscorners. Once the feature of interest is within the ROI, click the Teach button. The feature will be highlighted ingreen.2. Click the Save button to save the pattern to the first empty pattern storage slot.3. Set match criteria:iVu Plus TG Gen2 Image Sensorwww.bannerengineering.com - Tel: 763.544.3164 71