en_BA_RR30_IO-Link_V0.23.docx 14/40 Baumer Electric AG13.01.2021/ Frauenfeld, Switzerland4.3.5 Hysteresis Alignment ModeIn case of axial detection tasks like stop trigger or level detection, an accurate switching is required.To adapt the switching behavior and the hysteresis to the movement direction of the object, the alignment ofthe hysteresis can be changed.Parameter name Short Description Rights Unit / Allowed valuesSSC1 Config.Hyst Selects the hysteresis alignmentmoderw - Left Aligned- Center Aligned- Right Aligned (Default)4.3.5.1 Left AlignedLeft Aligned defines the hysteresis to be aligned towards the sensor / against the sensing direction.When to apply?- For an accurate switching distance in case the object is moving away from the sensoro Example: Detection of the low level of a tank to avoid a dry-runFigure 12 Left Aligned, Single Point Mode Figure 13 Left Aligned, Window Mode4.3.5.2 Right AlignedRight Aligned defines the hysteresis to be aligned away from the sensor / in sensing direction.When to apply?- For an accurate switching distance in case the object is moving towards the sensor.o Example: Stop trigger application, usual detection tasks.Figure 14 Right Aligned, Single Point Mode Figure 15 Right Aligned, Window Mode