en_BA_RR30_IO-Link_V0.23.docx 22/40 Baumer Electric AG13.01.2021/ Frauenfeld, Switzerland4.6.2 Disruption FilterThis filter allows you to ignore interfering objects when passing through the measuring range either cyclic ornon-cyclic. This function depends on two parametersParameter name Short Description Rights Unit / Allowed valuesProcess Value DisruptionFilter.Maximum perturbationtimeDuration (in units of time) until asignal (as defined in theparameter . Distance) becomesvisible at the output.rw Limits: 0 to 1000.000 msDefault: 200 msProcess Value DisruptionFilter.DistanceDistance deviations from thecurrent measured value whichare ignored, if shorter than theperiod set by the parameter“Process Value Disruption FilterMaximum perturbation time”.rw Limits 5 to 10.000 mmDefault: 300 mm4.6.3 Region of Interest (ROI)The region of interest is the space (in mm) in which the sensor performs. If a signal is detected in this region,the data will be processed and the result displayed. All signals, even if detected by the sensor, being out ofthis region are not processed and displayed further on. The ROI is not necessary the same as the analogoutput region. But the analog one has to be inside the bounders of the ROI. See 4.8.2.