en_BA_O200_IO-Link_V1.docx 32/34 Baumer Electric AG15.08.2018/ Frauenfeld, Switzerland5.3.2 Dynamic in Window Mode (Only O200.G)If the selected SSC is configured to Window mode (Section 4.3.2.1) during the dynamic teach-in theminimum and maximum values are evaluated. Setpoint SP1 is set to Min, SP2 is set to Max.Figure 29: Dynamic Window Teach, switching behavior6 DiagnosisIn addition to solving the primary application, the simple evaluation of secondary data, such as temperature,supply voltage or operating time, allows for predictive maintenance and thus optimum machine availability.6.1 Device StatusParameter name Short Description Rights Unit / AllowedvaluesDevice Status Indicates if the sensor isworking properlyro 0=Device is OK2=Out ofSpecification4=FailureDetailed Device Status ro6.2 Device TemperatureAn integrated temperature sensor allows to track the internal temperature of the sensor.Please be aware that compared to the ambient temperature the indicated values are higher due to theinternal heating of the sensor.The temperature may also vary due to mounting conditions and due to the electric load connected to theoutput.Parameter name Short Description Rights Unit / AllowedvaluesDevice Temperature.Current roUnit Selection.Temperature Choice of temperature unit(Default: °C)rw °C, °F, K