en_BA_O200_IO-Link_V1.docx 8/34 Baumer Electric AG15.08.2018/ Frauenfeld, SwitzerlandBit 8 to 15: ScaleValue is the exponent to the power of ten, applicable to the value of the Measurement Data Channel (MDC)Example:- Value of MDC 1000- Unit m- Scale -6- Means 1000*10-6 m or 1000 mAs O200 sensors only provide measuring values where no scale factor is required, the scale factor is setfixed to 0 (zero).Bit 16 to 31: MDC / Measurement ValueMDC stands for measurement data channel. Via this channel the distance value or the switch counts ofSSC1 or 4 can be read out as 16 bit integer value. See section 4.2 to learn how to configure the MDC.3.2.2 Process Data-OutThis data is cyclically sent from the master to the sensor (MasterSensor).IO-Link Process Data OutputBit:7 6 5 4 3 2 1 0Find Me (Localization: LEDsflashing)DisableTransmit LEDBit 0: Disable Transmit LEDIf set to true, the transmition LED is deactivated. The sensor will not deliver a measurement or switchingvalue. This can be useful to measure neighbouring sensors sequentially or to perform functional tests.Bit 1: Find Me FunctionSignalling e.g. by flashing LEDs on the sensor to locate and physically identify a sensor in a machine orsystem. The signalling can be triggered, for example, from the engineering tool of the controller.