INSTALLATION REQUIREMENTS/SPECIFICATIONS2-62.3.5 Transceiver RequirementsWhen you connect an external network segment, via a transceiver, to theMRXI with an EPIM-A, the following requirements must be met:• The transceiver or Ethernet Device to which the module will beconnected must meet IEEE 802.3 standards, and/or Ethernet Version1.0 or Version 2.0 standards.• The Signal Quality Error (SQE) test function on the transceiver mustbe disabled if you connect it to a repeater or to an Ethernet Version 1.0device. In addition, some Version 2.0 equipment does not support theSQE test. Devices that do not support SQE test interpret the SQE testpulse as a collision.2.3.6 AUI Cable RequirementsWhen you connect an external network segment to the MRXI with anEPIM-A or EPIM-X, the AUI cable must meet the followingrequirements:• AUI Cable - The AUI cable connecting the module to a device mustbe IEEE 802.3 type cable.• Length - The AUI Cable must not exceed 50 meters in length. If 28AWG thin office drop AUI cable is used, then the maximum cablelength is limited to 50 feet (15.24 meters).• Grounding - The connector shell of the EPIM-A and the EPIM-X areconnected to ground.