INSTALLATION REQUIREMENTS/SPECIFICATIONS2-14RCV (yellow): Indicates that the repeater is receivinga data packet on that segment.CPU (flashing green): This LED alternates from red to greenduring power up. After the boot iscomplete, the LED flashes green. Aflashing green LED indicates normaloperation. A red LED indicates a faultin the processor.POWER SUPPLY REQUIREMENTSNote: The MRXI has a universal power supply. This unit allows you to usean input power from 85 to 264 VAC, 47-63 Hz.Parameter Typical WorstValue CaseInput Current: 0.5 A 0.75 AOverload Protection - Output: (1) 2AG 1 amp fuse.ENVIRONMENTAL REQUIREMENTSOperating Temperature: +5° to +50° CNon-operating Temperature: -30° to +90° COperating Humidity: 5 to 95% (non-condensing)SAFETYDesigned in accordance with UL478, UL910, NEC 725-2(b), CSA,IEC, TUV, VDE class A. Meets FCC part 15, Class A limits.Warning: It is the responsibility of the person who sells the system towhich the MRXI will be a part to ensure that the total system meetsallowed limits of conducted and radiated emissions.