Chapter 77-33b) I/O DISPLAYThe status of each sensor and switch is shown in the display.Sensor and switch status is shown in the display.ON = 1OFF or not used = 0Screen 1T-7-33Screen 2T-7-34Screens 1 and 2 are selectable with the [ ] and [ ] buttons.These screens display the associated sensor status as listed in the table below.T-7-35I / O D I S P L A Y 1 Upper row0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Lower row1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 (Display position)I / O D I S P L A Y 2 Upper row0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Lower row17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 (Display position)Displayposition Sensor name LCD display contents1 Pump Cam Sensor 0: Sensor ON , 1: Sensor OFF2 Valve Open/Closed Detection Sensor 0: Sensor ON , 1: Sensor OFF3 (Not Used) -4 (Not Used) -5 Spur Cam Sensor 0: Sensor ON , 1: Sensor OFF6 Lift Cam Sensor 0: Sensor ON , 1: Sensor OFF7 Feed Roller HP Sensor 0: Sensor ON , 1: Sensor OFF8 Top Cover Sensor 0: Cover open , 1: Cover close9 (Not Used) -10 Ink Tank Cover Switch 0: Cover open , 1: Cover close11 (Not Used) -12 Paper Detection Sensor 0: Sensor ON , 1: Sensor OFF13 (Not Used) -14 (Not Used) -15 (Not Used) -16 (Not Used) -17 Roll Media Sensor 0: Sensor ON , 1: Sensor OFF18 Roll Cam Sensor 0: Sensor ON , 1: Sensor OFF19 (Not Used) -20 Cutter Right Position Sensor 0: Sensor ON , 1: Sensor OFF21 Cutter HP Sensor 0: Sensor ON , 1: Sensor OFF22 (Not Used) -23 (Not Used) -24 (Not Used) -25 (Not Used) -26 Roll unit detection 0: Roll unit not detected , 1: Roll unit detected27 (Not Used) -28 (Not Used) -29 (Not Used) -30 (Not Used) -31 (Not Used) -32 (Not Used) -