Chapter 88-298.3.3 Errors 0024-9331iPF6300 / iPF6350 / iPF6300S* Codes represent the numbers that are displayed in DISPLAY in service mode.If the same message is displayed when the printer is turned off, then back on, take action as recommended in the Action column.T-8-7Display massage Code* Condition detected ActionProblem with PrintheadChk printing results01800500-1010 The number of the printhead's non-discharge nozzlewas over fixed level during the non-dischargedetection operation.Clean the printhead.Replace the printhead.Problem with Printhead RChk printing results01800500-1012 The number of the right printhead's non-dischargenozzle was over fixed level during the non-dischargedetection operation.Clean the printhead.Replace the right printhead.Problem with Printhead LChk printing results01800500-1013 The number of the left printhead's non-dischargenozzle was over fixed level during the non-dischargedetection operation.Clean the printhead.Replace the left printhead.Move the blue platen switchNo.02 to the right.01861007-1056 The platen shutter switch No.2 has been closing whenshutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Move the blue platen switchNo.03 to the right.01861008-1057 The platen shutter switch No.3 has been closing whenshutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Move the blue platen switchNo.04 to the right.01861009-1058 The platen shutter switch No.4 has been closing whenshutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Move the blue platen switchNo.05 to the right.0186100A-1059 The platen shutter switch No.5 has been closing whenshutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Move the blue platen switchNo.06 to the right.0186100B-105A The platen shutter switch No.6 has been closing whenshutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Move the blue platen switchNo.07 to the right.0186100C-105B The platen shutter switch No.7 has been closing whenshutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Move the blue platen switchNo.08 to the right.0186100D-105C The platen shutter switch No.8 has been closing whenshutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Move the blue platen switchNo.09 to the right.0186100E-105D The platen shutter switch No.9 has been closing whenshutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Move the blue platen switchNo.10 to the right.0186100F-105E The platen shutter switch No.10 has been closingwhen shutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Move the blue platen switchNo.11 to the right.01861010-105F The platen shutter switch No.11 has been closingwhen shutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Move the blue platen switchNo.12 to the right.01861011-1060 The platen shutter switch No.12 has been closingwhen shutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Move the blue platen switchNo.13 to the right.01861012-1061 The platen shutter switch No.13 has been closingwhen shutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Move the blue platen switchNo.14 to the right.01861013-1062 The platen shutter switch No.14 has been closingwhen shutter is the mode of opening.Check the opening or closing of the platen shutterswitch.Check the platen and multi sensor and surroundingparts.Replace the multi sensor.Paper size not detected.Reload paper.03010000-200A Unable to detect the paper width (Paper loaded at animproper position)Reload the paper