10E E7/16"[11]4 9/16"[115.5]1/4"[7.0]5' 7-3/8"[1711.3]1' 4-13/16"[427] INSIDE1-3/4"[44.4]2-3/8"[61]1-3/4"[44.5]1.00"[25.4]"A"1-3/4"[44.4]21.74"[552.2]5.42"[137.7]11.96"[303.8]4.96"[126.0] 70.87"[1800.2]40.69"[1033.5]21.84"[554.7]16.03"[407.2]1.75"[44.5] 20.41"[518.3]3.00"[76.2]13.78"[350.0]14.00"[355.6]3.00"[76.2]15.19"[385.8]32.19"[817.6]3'-1 3/16"[944.6]"A"1-3/4"[44.5]CRBTMPWR001A01 3/4" [19] NPT3/4" [19] NPT1/2" [12.7] NPTCRRFCURB002A01CONNECTOR PKG. ACC. GAS CONNECTION TYPE GAS FITTING POWER WIRINGFITTINGCONTROL WIRINGFITTINGACCESSORY CONVENIENCEOUTLET WIRING CONNECTORTHRU THE CURB1/2" [12.7] NPT 1/2" [12.7] NPTCRBTMPWR003A01 THRU THE BOTTOMROOF CURBACCESSORY # ACRRFCURB001A01 14"[356]24"[610]ECN NO.APP'DCHK'DBYDATEREVISION RECORDREV1067898--MMC04/22/13OVERALL DIM. 5'-7 3/8" WAS 5'-7 7/8; 18GAMATERIAL WA 16 GA.; NAIL FIELD SUPPLIED WASWITH CURBADRAWING RELEASE LEVEL: PRODUCTIONTHIRD ANGLEPROJECTIONUNLESS OTHERWISE SPECIFIEDDIMENSIONS ARE IN INCHESTOLERANCES ON: THIS DOCUMENT AND THE INFORMATION CONTAINED THEREINIS PROPRIETARY TO CARRIER CORPORATION AND SHALL NOTBE USED OR DISCLOSED TO OTHERS, IN WHOLE OR IN PART,WITHOUT THE WRITTEN AUTHORIZATION OF CARRIER CORPORATION.1 DEC 2 DEC 3 DEC ANGMATERIAL - - - ----AUTHORIZATION NUMBER TITLE1041738 CURB ASY, ROOFENGINEERING MANUFACTURING (004-007)ENGINEERING REQUIREMENTS - - - - SIZE DRAWING NUMBER REVT-005, Y-002 DRAFTER CHECKERD 48TC400427 BWEIGHT: - MMC 06/17/11 - - SHEET 5 OF 5SURFACE FINISH MFG/PURCH MODEL (INTERNAL USE ONLY) NEXT DRAWING SCALE DISTRIBUTION- PURCH - N/A MMCNOTES:1. ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED.2. INSULATED PANELS: 25.4 [1"] THK. POLYURETHANE FOAM, 44.5 [1-3/4] # DENSITY.3. DIMENSIONS IN [ ] ARE IN MILLIMETERS.4. ROOFCURB: 18 GAGE STEEL.5. ATTACH DUCTWORK TO CURB. (FLANGES OF DUCT REST ON CURB).6. SERVICE CLEARANCE 4 FEET ON EACH SIDE.7. DIRECTION OF AIR FLOW.8. CONNECTOR PACKAGE CRBTMPWR001A01 IS FOR THRU-THE-CURB GAS TYPEPACKAGE CRBTMPWR003A01 IS FOR THRU-THE-BOTTOM TYPE GAS CONNECTIONS.TYPICAL (4) SIDESSUPPLY AIR RETURN AIRROOFING MATERIAL(FIELD SUPPLIED)CANT STRIP(FIELD SUPPLIED)ROOFING FELT(FIELD SUPPLIED)COUNTER FLASHING(FIELD SUPPLIED)UNITGASKET(SUPPLIED WITH CURB)RIGID INSULATION(FIELD SUPPLIED)DUCT(FIELD SUPPLIED)NAIL (FIELD SUPPLIED)CERTIFIED DRAWINGVIEW "B"CORNER DETAILSEE VIEW "B"RETURN AIRSUPPLY AIRSUPPLY AIROPENINGRETURN AIROPENINGGAS SERVICE PLATETHRU THE CURBDRILL HOLE2" [50.8] @ASSEMBLY (IFREQUIRED)(SEE NOTE #8)SEE NOTE #211 3/4"[298.5] WIDEINSULATED DECK PANELS8 9/16"[217.5] WIDEINSULATED DECK PANEL1/3/4"[44.5]SCALE 0.250E-ESECTIONC13310Fig. 6 -- Roof Curb Details