Features and Specifications 13© Travis Industries 10/10/18 - 1418 DaVinci-Cat2+Category 3 Dimensions – Single Sided or See Through Configurations(a) Air intake – See table below for quantity - Location determined by fireplace length (see “Air Intake Duct Location” on page 69).(b) Vent Collar – Uses 10” or 8” Diameter B-Vent (determined by power vent type). Centered on module.(c) Gas Control Valve – Located to the front of the master module (front of fireplace is determined by gas control valve location).(d) Electrical Junction Box – On master module (location determined at time of order – can be relocated), includes 120v input,exhaust vent power/harness, on-off LED harness.(e) Gas Inlet – On master module (NOTE: gas inlet is always located along the front edge, even if master module is to the left).(f) Vent Collar Distance to Front/Back – Approx. 4.375” (112mm) for 10” B-Vent, 5.375” (137mm) for 8” B-VentNOTE: When using a 2-sided fireplace, the front is determined by the gas control valve (it is to the front).Important Notes Regarding FramingWe strongly suggest framing around the fireplace after it is in place. If you do frame beforefireplace placement, add 6” to each side (12” total) to allow for fireplace assembly.Horizontal Dimensions & SpecificationsVersion Width (x) Vent Loc. (y) Air Intakes Power Vent BTUs Min. Weight132” 1 Sided / See Through 134" (3404mm) * 6 * 159,500 2150 lbs. 958Kg144” 1 Sided / See Through 146" (3709mm) * 6 * 174,000 2300 lbs. 1024Kg156” 1 Sided / See Through 158" (4014mm) * 6 * 188,500 2450 lbs. 1091Kg168” 1 Sided / See Through 170" (4318mm) * 6 * 203,000 2600 lbs. 1158Kg180” 1 Sided / See Through 182" (4623mm) * 6 * 217,500 2750 lbs. 1225Kg* Primary vent is centered on the fireplace. Power vent configuration is determined at the time of order.FrontavantRightdroitReararrie'reLefta' gauchex