42 Installation (for qualified installers only)© Travis Industries 6/19/18 - 1418 DaVinci-Cat2+Typical Framing Dims. – See Through ConfigurationImportant Notes Regarding FramingWe strongly suggest framing around the fireplace after it is in place. If you do frame beforefireplace placement, add 6” to each side to allow for fireplace assembly. Dimension “x”shown in the table below includes the extra 6” to each side.Version Width (x) Height (y)12” GlassHeight (y)20” GlassHeight (y)30” GlassHeight (y)36” GlassHeight (y)58” GlassCategory 2 72” See Through 86” (2185mm)50.625”(1286mm)58.625”(1490mm)68.625”(1744mm)74.625”(1896mm)96.625”(2455mm)84” See Through 98” (2490mm)96” See Through 110” (2794mm)108” See Through 122” (3099mm)120” See Through 134” (3404mm)Category 3 132” See Through 146" (3709mm)144” See Through 158" (4014mm)156” See Through 170" (4318mm)168” See Through 182" (4623mm)180” See Through 194" (4928mm)19.625"499mmWhen using a top plate, you may need to notch it atthe center to provide adequate vent clearance.3" (77mm) Maximum for vent clearance.Do not place vertical framing directly in thecenter above the fireplace - it will infringeupon the vent clearance requirements.xy