Installation (for qualified installers only) 49© Travis Industries 6/19/18 - 1418 DaVinci-Cat2+Accessing Internal ComponentsMost internal components can be accessed by removing the front glass pane and intake air channelmedia tray (see instructions below). If more extensive access is required, see “burner removal” on thefollowing page.-- Turn off gas to the fireplace prior to accessing internal components to prevent accidental ignition.-- Shut off electricity to the fireplace to protect internal circuits.Remove the front outer glass pane (see page 93). Remove the intake air channel media tray.At this point most of the internal components may be accessed (see descriptions below).Internal Shut Off Valve AccessThe internal shutoff is accessed following the directions above. The valve is positioned near the gas inlet(left, right, or bottom).NOTE: The shut off valve must be closed while pressure testing the gas line leading to the fireplace.LED Controller- May be placed on its side- May be on right sideLEFT SIDE RIGHT SIDEBurner Air Shutter Shutoff Valve- May be on left sideAir PressureSwitchCENTERRheostatFireplace Controller Gas Control ValvePower Vent Controller