SiUS331604E Field Setting from Remote ControllerField Setting 84Note:1. Settings are made simultaneously for the entire group, however, if you select the mode No. insideparentheses, you can also set units individually. Setting changes however cannot be checked except in theindividual mode in parentheses.∗2. The mode numbers inside parentheses cannot be used by wireless remote controllers, so they cannot be setindividually. Setting changes also cannot be checked.3. Do not make settings other than those described above. Nothing is displayed for functions the indoor unit isnot equipped with.4. 88 or Checking the connection. Please stand by. may be displayed to indicate that the remote controller isresetting when returning to normal mode.∗5. If the setting mode is set to Equipped, heat reclaim ventilation fan conducts the fan residual operation bylinking to the indoor unit.∗6. Only for FXTQ∗7. For FXTQ: Factory setting is 02.∗8.13(23) 0 Setting of normal airflow N H S — (19)1 Selection of airflow direction(Set when a sealing material kit has been installed.)F (4 directions) T (3 directions) W (2directions)— (20)2 Swing pattern settings(In case of an infrared floor sensor is installed) All directionsynchronizedswing— Facing swing — (21)3 Operation of downward flow flap Equipped Not equipped — — (22)4 Setting airflow position Draft prevention Standard CeilingSoilingprevention— (23)5 Setting of static pressure selection Standard High staticpressure— — (24)6 External Static Pressure Settings Refer to page 94. (25)14(24)4 (∗6) Setting of Humidifier / Air Purifier Fan Tap Remotecontroller setting H tap — — (26)5 (∗6) Residual Operation Time 30 seconds 60 seconds 120 seconds — (27)15(25) 1 Thermostat OFF excess humidity Not equipped Equipped — — (28)2 Direct duct connection(when the indoor unit and Heat ReclaimVentilator are connected by duct directly.) (∗5)Not equipped Equipped — — (29)3 Drain pump and humidifier interlock selection Not equipped Equipped — — (30)5 Selection for individual ventilation setting byremote controllerNot equipped Equipped — — (31)1b (2b) 3 Display of Contact Center Displayed Not displayed — — (32)4 Display of error codes on the remote controller — Two-digit display — Four-digitdisplay (33)12 Key-lock pattern settings No operationallowed (Cancelprocedure isdisplayed.)No operationallowed (Cancelprocedure is notdisplayed.)No menuoperation isallowed(Cancelprocedure isdisplayed.)No menuoperation isallowed anytime.(34)14 Setting restricted/permitted for airflow block Refer to page 96. (35)1c (2c) 0 Room temperature display Roomtemperature isnot displayedRoomtemperature isdisplayed— — (36)ModeNo.(∗2)FirstCodeNo.Description Second Code No. DetailsNo.01 02 03 04Set temperatureThermostatOFFThermostatON