7.2 APOSS Software MessagesThe APOSS software messages are arranged in alphabeticalorder. Letters following a % sign represent variables whichcan be used in plain text at the corresponding locations.Compilation error(s): program not saved!A file is always compiled first and then saved. If you wantto save the program, for example in the menu Controller →Save program and a syntax error is found duringcompilation this message will be displayed.Start the → Syntax Check in the menu Development, correctthe syntax error and then save the program.Connection to ... already exists . . .Connection to %d already exists [%s] - change to Window?When opening a new window, or when trying to connecta window with a controller that is already linked to awindow.Yes: The controller is disconnected from the old windowand linked to the new window.No: The controller stays connected to the old window.The new window is not linked to a controller.Connector pin is not validConnector %d pin %d is not valid in line %d column %dAn illegal combination or a pin number which cannot beset is used with the OUT command.Controller is executing a program or command!When the controller is executing a command or program itis not available for additional commands. You have toBreak the new command and re-start it once the previouscommand has been completely.Error in array part of fileWhen re-saving a configuration (e.g. Controller →Parameters → Restore from file) the computer recognizesthat the data in the array area is formatted incorrectly.In order to be able to save a file, the following conditionsmust be fulfilled:- Identical software versions,- same configuration (e.g. same number of axes),- in the case that arrays have already beeninputted, these must match the ones that are tobe saved in terms of type and size.Error in axis parameter part of fileWhen re-saving a configuration (e.g. Controller →Parameters → Restore from file) the computer recognizesthat the data in the area of the axis parameters isformatted incorrectly. The parameter number and thesequence must be correct and numbering must becontinuous.In order to be able to save a file, the following conditionsmust be fulfilled:- Identical software versions, that provides samenumber and order of the parameters,- same configuration (e.g. same number of axes).Error in global parameter part of fileWhen re-saving a configuration (e.g. Controller →Parameters→ Restore from file) the computer recognizesthat the data in the area of the global parameters isformatted incorrectly.In order to be able to save a file, the following conditionsmust be fulfilled:- Identical software versions, that provides samenumber and order of the parameters,- same configuration (e.g. same number of axes).Lost connection to ...If the VLT AutomationDrive is turned off or the plug ispulled, etc. the window is disconnected from the VLTAutomationDrive and the lost connection is registered.Timeout: no reply from FCThe VLT AutomationDrive does not answer; check theconnection.Troubleshooting MCO 305 Operating Instructions34 MG.33.K3.02 - VLT® is a registered Danfoss trademark77