VLT® AQUA Drive FC 202 N500 N560High/normal load HO NO HO NO(High overload=150% current during 60 s, normal overload=110%current during 60 s)Typical shaft output at 400 V [kW] 450 500 500 560Typical shaft output at 460 V [hp] 600 650 650 750Enclosure size E2h/E4h E2h/E4hOutput current (3-phase)Continuous (at 400 V) [A] 800 880 880 990Intermittent (60 s overload)(at 400 V) [A] 1200 968 1320 1089Continuous (at 460/500 V) [A] 730 780 780 890Intermittent (60 s overload)(at 460/500 V) [A] 1095 858 1170 979Continuous kVA (at 400 V) [kVA] 554 610 610 686Continuous kVA (at 460 V) [kVA] 582 621 621 709Maximum input currentContinuous (at 400 V) [A] 771 848 848 954Continuous (at 460/500 V) [A] 704 752 752 858Maximum number and size of cablesper phase (E2h)- Mains and motor without brake [mm2 (AWG)]1) 6x240 (6x500 mcm) 6x240 (6x500 mcm)- Mains and motor with brake [mm2 (AWG)1) 5x240 (5x500 mcm) 5x240 (5x500 mcm)- Brake or regeneration [mm2 (AWG)1) 2x185 (2x350 mcm) 2x185 (2x350 mcm)Maximum number and size of cablesper phase (E4h)- Mains and motor without brake [mm2 (AWG)]1) 6x240 (6x500 mcm) 6x240 (6x500 mcm)- Mains and motor with brake [mm2 (AWG)1) 2x185 (2x350 mcm) 2x185 (2x350 mcm)- Load share or regeneration [mm2 (AWG)1) 4x185 (4x350 mcm) 4x185 (4x350 mcm)Maximum external mains fuses [A]2) 1200 1200Estimated power loss at 400 V [W]3) 4) 8352 9473 9449 11102Estimated power loss at 460 V [W]3) 4) 7182 7809 7771 9236Efficiency4) 0.98 0.98Output frequency [Hz] 0–590 0–590Heat sink overtemperature trip [°C (°F)] 110 (230) 100 (212)Control card overtemperature trip [°C (°F)] 80 (176) 80 (176)Power card overtemperature trip [°C (°F)] 85 (185) 85 (185)Fan power card overtemperature trip [°C (°F)] 85 (185) 85 (185)Active in-rush card overtemperature trip [°C (°F)] 85 (185) 85 (185)Table 7.2 Technical Specifications, Mains Supply 3x380–480 V AC1) American Wire Gauge.2) For fuse ratings, see chapter 10.5 Fuses and Circuit Breakers.3) Typical power loss is at normal conditions and expected to be within±15% (tolerance relates to variety in voltage and cable conditions.) Thesevalues are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies fordimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical controlcard power consumptions are included. For power loss data according to EN 50598-2, refer to www.danfoss.com/vltenergyefficiency. Options andcustomer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B each add only 4 W.4) Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energyefficiency class, see chapter 7.5 Ambient Conditions. For part load losses, see www.danfoss.com/vltenergyefficiency.Specifications Design GuideMG22B102 Danfoss A/S © 05/2017 All rights reserved. 337 7