Symbologies320 Gryphon™ I GD4100/GM4100Code 11 Set Length 2This feature specifies one of the barcode lengths for Code 11 Length Control. Length 2 is themaximum label length if in Variable Length Mode, or the second fixed length if in FixedLength Mode. Length includes the barcode’s check and data characters.The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (onlyone fixed length).Follow these instructions to set this feature:1. Determine the desired character length (from 2 to 50 — or 0 to ignore this length). Padthe number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20,etc.2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter ProgrammingMode.3. Scan the barcode: SELECT CODE 11 LENGTH 2 SETTING.4. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that representthe length setting which was determined in the steps above. You will hear a two-beep indi-cation after the last character.NOTE5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit ProgrammingMode.This completes the procedure. See Table 38 for some examples of how to set this feature.Table 38. Code 11 Length 2 Setting ExamplesSTEP ACTION EXAMPLES1 Desired Setting (pad withleading zeroes)00 (Ignore ThisLength) 07 Characters 15 Characters 50 Characters2 Scan ENTER/EXIT PROGRAMMING MODE3 Scan SELECT CODE 11 LENGTH 2 SETTING4 Scan Two Characters FromAppendix E, Keypad ‘0’ and ‘0’ ‘0’ and ‘7’ ‘0’ and ‘F’ ‘3’ AND 2’5 Scan ENTER/EXIT PROGRAMMING MODEIf you make a mistake before the last character, scan the CANCELbarcode to abort and not save the entry string. You can then startagain at the beginning.