Symbologies334 Gryphon™ I GD4100/GM4100GS1 DataBar™ Expanded Set Length 2This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control.Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length ifin Fixed Length Mode. Length includes the barcode’s data characters only.The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length (onlyone fixed length).Follow these instructions to set this feature:1. Determine the desired character length (from 1 to 74). Pad the number with leadingzeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter ProgrammingMode.3. Scan the barcode: SELECT GS1 DataBar™ EXPANDED LENGTH 2 SETTING.4. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that representthe length setting which was determined in the steps above. You will hear a two-beep indi-cation after the last character.NOTE5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit ProgrammingMode.This completes the procedure. See Table 40 for some examples of how to set this feature.Table 40. GS1 DataBar™ Expanded Length 2 Setting ExamplesSTEP ACTION EXAMPLES1 Desired Setting 00 (ignore secondlength) 07 Characters 52 Characters 74 Characters2 Scan ENTER/EXIT PROGRAMMING MODE3 Scan SELECT GS1 DataBar™ EXPANDED LENGTH 2 SETTING4 Scan Two Characters FromAppendix E, Keypad ‘0’ and ‘0’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ and ‘4’5 Scan ENTER/EXIT PROGRAMMING MODEIf you make a mistake before the last character, scan the CANCELbarcode to abort and not save the entry string. You can then startagain at the beginning.