LED and Beeper Indications388 Gryphon™ I GD4100/GM4100Table 50Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.Label Program-ming ModeEntryA valid programming label hasbeen scanned. LED blinks continuously Reader sounds four low frequency beeps.Label Program-ming ModeRejection ofLabelA label has been rejected. N/AReader sounds three times atlowest frequency & current vol-ume.Label Program-ming ModeAcceptance ofPartial LabelIn cases where multiple labelsmust be scanned to programone feature, this indicationacknowledges each portion asit is successfully scanned.N/A Reader sounds one short beep at highestfrequency & current volume.Label Program-ming ModeAcceptance ofProgrammingConfiguration option(s) havebeen successfully programmedvia labels and the reader hasexited Programming Mode.N/AReader sounds one high fre-quency beep and 4 low fre-quency beeps followed byreset beeps.Label Program-ming Mode Can-cel Item EntryCancel label has been scanned. N/AReader sounds two times atlow frequency and current vol-ume.. Programming Mode IndicationsError CodesUpon startup, if the reader sounds a long tone, this means the reader has not passed itsautomatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader isreset, the sequence will be repeated. The following table describes the LED flashes/beep codesassociated with an error found.NUMBER OF LEDFLASHES/BEEPS ERROR CORRECTIVE ACTION1 ConfigurationContact Helpdesk for assistance2 Interface PCB4 Reader Module5 Laser Pointer (if so equipped)6 Digital PCB14 CPLD/Code Mismatch