Scanning FeaturesProduct Reference Guide 53Scanning Active TimeThis setting specifies the amount of time that the reader stays in scan ON state once the state isentered. The range for this setting is from 1 to 255 seconds in 1-second increments.Follow these instructions to set this feature:1. Determine the desired setting.2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20= 020, etc.3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter ProgrammingMode.4. Scan the barcode: SELECT SCANNING ACTIVE TIME SETTING.5. Scan the appropriate three digits from the keypad in Appendix E, Keypad, that representthe duration which was determined in the steps above. You will hear a two-beep indica-tion after the last character.NOTE6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit ProgrammingMode.This completes the procedure. See Table 3 for some examples of how to set this feature.Table 3. Scanning Active Time Setting ExamplesSTEP ACTION EXAMPLES1 Desired Setting 1 Second 90 Sec. (1.5min.) 180 Sec. (3 min.) 255 Seconds (4.25min.)2 Pad leading zero(es) 001 090 180 2553 Scan ENTER/EXIT PROGRAMMING MODE4 Scan SELECT SCANNING ACTIVE TIME SETTING5 Scan Three CharactersFrom Appendix E, Keypad ‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’6 Scan ENTER/EXIT PROGRAMMING MODEIf you make a mistake before the last character, scan the CANCELbarcode to abort and not save the entry string. You can then startagain at the beginning.