Diagnostic information 2-127Sensor (input) early jam service check5 Check the above sensor for proper connection.Is the above sensor connected properly?Replace thesensor (input).Go to “Sensor(input) removal”on page 4-71.Replace theconnection.6 Check the sensor (fuser output) for proper operation.1. Enter the diagnostic mode2. Select Base sensor test3. Observe the line item “exit”Caution: The area around the actuator is very hot. Allow thefuser area to cool before proceeding.Does the display on the operator panel, change every timethe sensing area of the above sensor is interrupted orblocked?Go to step 8. Go to step 7.7 Check the above sensor for proper connection.Is the above sensor connected properly?Replace the fuserunit assembly.Go to “Fuser unitassemblyremoval” onpage 4-22.Replace theconnection.8 Perform a print test and check the main motor assembly.Is the media properly transported and able to reach thesensor (fuser output)?Replace the maindrive motorassembly.Go to “Outputcover assemblyremoval” onpage 4-54.Replace theconnection.9 Check the aligner assembly for obstructions.Is the above component free from obstructions?Go to step 10. Removeobstructions.10 Perform a print test.Does the problem remain?Contact nexthighest level oftech support.Problem solved.Use this procedure for the following jams:• 200.04 • 200.06 • 200.08 • 200.14 • 200.33Step Check Yes No1 Check media origination.Did the media originate from the MPF?Go to step 2. Go to step 5.2 Check the MPF pick roll assembly.Is the above component free of excess wear andcontamination?Go to step 3. Clean or replacethe MPF pick rollassembly.Go to “MPF pickroll assemblyremoval” onpage 4-37.Step Check Yes No