WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSONDisconnect from electricity and gas before servicing. Check appliance is safe when you have finished.31ArtNo.270-0019 - Proplus tags 1Conversion from Natural Gas (1.0 kPa)to LPG X Propane (2.54 kPa)nn This conversion must be performed by a competentperson, in accordance with these instructions andwith the local supply company requirements. Readthe instructions before converting this appliance.nn Failure to convert the appliance correctly couldinvalidate any warranty or liability claims and leadto prosecution.nn The conversion instructions must be used inconjunction with the rest of the applianceinstruction, in particular for information onStandards, cooker positioning, connection, hosesuitability, etc.nn When servicing or replacing gas-carryingcomponents, disconnect from the gas beforestarting, and check that the appliance is gas soundafter completion.nn DO NOT use reconditioned or unauthorised gascontrols.nn Disconnect from the electricity supply beforeconversion. Before electrical reconnection, checkthat the appliance is electrically safe.InjectorsRemove the burner caps and heads. Remove the old injectors.Fit the new injectors: see ‘Technical Data’ section for correctinjectors. Reassemble in the reverse order (Fig.8-1).Tap AdjustmentPull off all the control knobs. Remove the 4 fixing screwsunderneath the control panel.The control panel will drop down slightly. It is held at the topby two holes in the top edge, one at each end, that locate onthe tags on the inner panel (Fig.8-2). Lift the control panelclear of the tags and pull forwards, taking care not to damageor strain the wiring.Using a pair of long nosed pliers, carefully remove the bypassscrew and fit the correct replacement screw (Fig.8-3); see‘Technical Data’ for the correct size. Tighten the screw down.Refit the control panel.8. Conversion to Propane GasABCArtNo.311-0010 InjectorsFig.8-1ArtNo.102-0015 - Soudillon tap bypass screwAFig.8-3Fig.8-2A – Tap bypass screwA – Injector, B – Internal injector, C – External injectorDocNo.080-0003 - Gas conversion - 110RM - Tag-fit fascia