Control card, 10 V DC outputTerminal number 50Output voltage 10.5 V ±0.5 VMax. load 25 mAThe 10 V DC supply is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.Control characteristicsResolution of output frequency at 0–1000 Hz ±0.003 HzSystem response time (terminals 18, 19, 27, 29, 32, 33) ≤ 2 msSpeed control range (open-loop) 1:100 of synchronous speedSpeed accuracy (open-loop) 30-4,000 rpm: Maximum error of ±8 rpmAll control characteristics are based on a 4-pole asynchronous motorSurroundingsEnclosure, frame size 4X and 5X IP00, IP21, IP54Enclosure, frame size 6X IP21, IP54Vibration test 0.7 gRelative humidity 5%–95% (IEC 721-3-3; Class 3K3 (non-condensing) during operationAggressive environment (IEC 60068-2-43) H 2S test class kDTest method according to IEC 60068-2-43 H2S (10 days)- with derating max. 131° F [55°C] 1)- with full output power, typical EFF2 motors max. 122° F [50°C]1)- at full continuous drive output current max. 113° F [45°C]1)1) For more information on derating see the AF-600 FP, section on Special Conditions.Minimum ambient temperature during full-scale operation 32° F [0°C]Minimum ambient temperature at reduced performance 14° F [-10°C]Temperature during storage/transport -13°–149°/158° F [-25°–+65°/70°C]Maximum altitude above sea level without derating 3,300 ft [1,000 m]Maximum altitude above sea level with derating 10,000 ft [3,000 m]Derating for high altitude, see section on special conditions in the Design GuideEMC standards, Emission EN 61800-3, EN 61000-6-3/4, EN 55011, IEC 61800-3EMC standards, ImmunityEN 61800-3, EN 61000-6-1/2,EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6See section on special conditions in the Design Guide!Control card performanceScan interval 5 msControl card, USB serial communicationUSB standard 1.1 (Full speed)USB plug USB type B “device” plugCAUTIONConnection to PC is carried out via a standard host/device USB cable.The USB connection is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.The USB connection is not galvanically isolated from ground protection. Use only isolated laptop/PC as connection to theUSB connector on the adjustable frequency drive or an isolated USB cable/drive.Specifications AF-600 FP Design and Installation GuideDET-768A 12-1512 12