– 64 –Microwave Speedcook* Convection Broil** Toast** Warm ProofUpperHeater (1)Not Available Cycles by PL(See PL Chart)Not Available On On NotAvailableNotAvailableUpperHeater (2)Not Available Cycles by PL(See PL Chart)Not Available On On NotAvailableNotAvailableLowerHeaterNot Available Cycles by PL(See PL Chart)PL1 for rst15 minutes oruntil preheatcomplete.(SeeConvectionChart)On On NotAvailableNotAvailableHigh Voltage Cycles by PL(See PL Chart)Cycles by PL(See PL Chart)NotAvailableNotAvailableNotAvailableNotAvailableNotAvailableConvectionHeaterNot Available Cycles byPL (SeeConvectionChart)Preheats toand cyclesaround usersset point.Cycles at450°FCycles at450°FCyclesfrom169°F to195°F.Cycles at95°F.ConvectionFanOff Always onexcept Conv.PL 0 then Off.On On On On OnDamper Open Closed Closed Closed Closed Closed(Moist)Open(Crispy)ClosedTT Motor On On On On On On OnOven Lamp(Cavity)On On On Off Off On OnUpperCoolingMotorOff On Off On On Off OffLowerCoolingMotorON On On On On Off OffVentilationMotorOff On Off On On Off OffMagnetronFanOn On On On On On OnLoad Algorithm Chart* In Speedcook, when power levels are set at 5 or above, (except convection), the power levels automatically cut back.After 10 minutes all heat sources except convection cut back to 70%, convection cuts back to 60 %. After 20 minutes,all except convection cuts back to 50%, convection remains at 60%. Voltage compensation and thermal compensationoccur in Speedcook.** Broil and toast cut back on upper and lower lamps just like speedcook.(Continued Next Page)Operating Charts