GE Multilin L60 Line Phase Comparison Relay B-15APPENDIX B B.4 MEMORY MAPPINGBExpanded Remote Input/Output Status (Read Only)2F00 Remote Device States, one per register (16 items) 0 to 1 --- 1 F155 0 (Offline)2F80 Remote Input States, one per register (64 items) 0 to 1 --- 1 F108 0 (Off)Oscillography Values (Read Only)3000 Oscillography Number of Triggers 0 to 65535 --- 1 F001 03001 Oscillography Available Records 0 to 65535 --- 1 F001 03002 Oscillography Last Cleared Date 0 to 400000000 --- 1 F050 03004 Oscillography Number Of Cycles Per Record 0 to 65535 --- 1 F001 0Oscillography Commands (Read/Write Command)3005 Oscillography Force Trigger 0 to 1 --- 1 F126 0 (No)3011 Oscillography Clear Data 0 to 1 --- 1 F126 0 (No)Fault Report Indexing (Read Only Non-Volatile)3020 Number of Fault Reports 0 to 65535 --- 1 F001 0Fault Report Actuals (Read Only Non-Volatile) (15 modules)3030 Fault Report 1 Time 0 to 4294967295 --- 1 F050 03032 Fault Report 2 Time 0 to 4294967295 --- 1 F050 03034 Fault Report 3 Time 0 to 4294967295 --- 1 F050 03036 Fault Report 4 Time 0 to 4294967295 --- 1 F050 03038 Fault Report 5 Time 0 to 4294967295 --- 1 F050 0303A Fault Report 6 Time 0 to 4294967295 --- 1 F050 0303C Fault Report 7 Time 0 to 4294967295 --- 1 F050 0303E Fault Report 8 Time 0 to 4294967295 --- 1 F050 03040 Fault Report 9 Time 0 to 4294967295 --- 1 F050 03042 Fault Report 10 Time 0 to 4294967295 --- 1 F050 03044 Fault Report 11 Time 0 to 4294967295 --- 1 F050 03046 Fault Report 12 Time 0 to 4294967295 --- 1 F050 03048 Fault Report 13 Time 0 to 4294967295 --- 1 F050 0304A Fault Report 14 Time 0 to 4294967295 --- 1 F050 0304C Fault Report 15 Time 0 to 4294967295 --- 1 F050 0Modbus File Transfer (Read/Write)3100 Name of file to read --- --- --- F204 (none)Modbus File Transfer (Read Only)3200 Character position of current block within file 0 to 4294967295 --- 1 F003 03202 Size of currently-available data block 0 to 65535 --- 1 F001 03203 Block of data from requested file (122 items) 0 to 65535 --- 1 F001 0Event Recorder (Read Only)3400 Events Since Last Clear 0 to 4294967295 --- 1 F003 03402 Number of Available Events 0 to 4294967295 --- 1 F003 03404 Event Recorder Last Cleared Date 0 to 4294967295 --- 1 F050 0Event Recorder (Read/Write Command)3406 Event Recorder Clear Command 0 to 1 --- 1 F126 0 (No)DCMA Input Values (Read Only) (24 modules)34C0 DCMA Inputs 1 Value -9999999 to 9999999 --- 1 F004 034C2 DCMA Inputs 2 Value -9999999 to 9999999 --- 1 F004 034C4 DCMA Inputs 3 Value -9999999 to 9999999 --- 1 F004 034C6 DCMA Inputs 4 Value -9999999 to 9999999 --- 1 F004 034C8 DCMA Inputs 5 Value -9999999 to 9999999 --- 1 F004 034CA DCMA Inputs 6 Value -9999999 to 9999999 --- 1 F004 034CC DCMA Inputs 7 Value -9999999 to 9999999 --- 1 F004 034CE DCMA Inputs 8 Value -9999999 to 9999999 --- 1 F004 034D0 DCMA Inputs 9 Value -9999999 to 9999999 --- 1 F004 034D2 DCMA Inputs 10 Value -9999999 to 9999999 --- 1 F004 034D4 DCMA Inputs 11 Value -9999999 to 9999999 --- 1 F004 034D6 DCMA Inputs 12 Value -9999999 to 9999999 --- 1 F004 0Table B–9: MODBUS MEMORY MAP (Sheet 8 of 47)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT