GE Multilin L60 Line Phase Comparison System B-35APPENDIX B B.4 MEMORY MAPPINGB67BE Reserved (3 items) 0 to 1 --- 1 F001 0Autoreclose 1P 3P (Read/Write Setting)6860 Autoreclose Mode 0 to 3 --- 1 F622 0 (Mode 1 (1 & 3Pole))6861 Autoreclose Maximum Number of Shots 1 to 4 --- 1 F001 26862 Autoreclose Block Breaker 1 0 to 4294967295 --- 1 F300 06864 Autoreclose Close Time Breaker 1 0 to 655.35 s 0.01 F001 106865 Autoreclose Breaker Manual Close 0 to 4294967295 --- 1 F300 06867 Autoreclose Function 0 to 1 --- 1 F102 0 (Disabled)6868 Autoreclose Block Time Manual Close 0 to 655.35 s 0.01 F001 10006869 Autoreclose 1P Initiate 0 to 4294967295 --- 1 F300 0686B Autoreclose 3P Initiate 0 to 4294967295 --- 1 F300 0686D Autoreclose 3P TD Initiate 0 to 4294967295 --- 1 F300 0686F Autoreclose Multi-Phase Fault 0 to 4294967295 --- 1 F300 06871 Autoreclose Breaker 1 Pole Open 0 to 4294967295 --- 1 F300 06873 Autoreclose Breaker 3 Pole Open 0 to 4294967295 --- 1 F300 06875 Autoreclose 3-Pole Dead Time 1 0 to 655.35 s 0.01 F001 506876 Autoreclose 3-Pole Dead Time 2 0 to 655.35 s 0.01 F001 1206877 Autoreclose Extend Dead T1 0 to 4294967295 --- 1 F300 06879 Autoreclose Dead T1 Extension 0 to 655.35 s 0.01 F001 50687A Autoreclose Reset 0 to 4294967295 --- 1 F300 0687C Autoreclose Reset Time 0 to 655.35 s 0.01 F001 6000687D Autoreclose Breaker Closed 0 to 4294967295 --- 1 F300 0687F Autoreclose Block 0 to 4294967295 --- 1 F300 06881 Autoreclose Pause 0 to 4294967295 --- 1 F300 06883 Autoreclose Incomplete Sequence Time 0 to 655.35 s 0.01 F001 5006884 Autoreclose Block Breaker 2 0 to 4294967295 --- 1 F300 06886 Autoreclose Close Time Breaker 2 0 to 655.35 s 0.01 F001 106887 Autoreclose Transfer 1 to 2 0 to 1 --- 1 F126 0 (No)6888 Autoreclose Transfer 2 to 1 0 to 1 --- 1 F126 0 (No)6889 Autoreclose Breaker 1 Fail Option 0 to 1 --- 1 F081 0 (Continue)688A Autoreclose Breaker 2 Fail Option 0 to 1 --- 1 F081 0 (Continue)688B Autoreclose 1P Dead Time 0 to 655.35 s 0.01 F001 100688C Autoreclose Breaker Sequence 0 to 4 --- 1 F082 3 (1 - 2)688D Autoreclose Transfer Time 0 to 655.35 s 0.01 F001 400688E Autoreclose Event 0 to 1 --- 1 F102 0 (Disabled)688F Autoreclose 3P Dead Time 3 0 to 655.35 s 0.01 F001 2006890 Autoreclose 3P Dead Time 4 0 to 655.35 s 0.01 F001 4006891 Autoreclose Bus Fault Initiate 0 to 4294967295 --- 1 F300 06893 Autoreclose Initiate Mode 0 to 1 --- 1 F610 0 (Protection ANDCB)6894 Autoreclose Mode Aut 0 to 3 --- 1 F622 0 (Mode 1 (1 & 3Pole))6895 Autoreclose Mode 1 Activation 0 to 4294967295 --- 1 F300 06897 Autoreclose Mode 2 Activation 0 to 4294967295 --- 1 F300 06899 Autoreclose Mode 3 Activation 0 to 4294967295 --- 1 F300 0689B Autoreclose Mode 4 Activation 0 to 4294967295 --- 1 F300 0Phase Undervoltage (Read/Write Grouped Setting) (3 modules)7000 Phase Undervoltage 1 Function 0 to 1 --- 1 F102 0 (Disabled)7001 Phase Undervoltage 1 Signal Source 0 to 5 --- 1 F167 0 (SRC 1)7002 Phase Undervoltage 1 Pickup 0 to 3 pu 0.001 F001 10007003 Phase Undervoltage 1 Curve 0 to 1 --- 1 F111 0 (Definite Time)7004 Phase Undervoltage 1 Delay 0 to 600 s 0.01 F001 1007005 Phase Undervoltage 1 Minimum Voltage 0 to 3 pu 0.001 F001 1007006 Phase Undervoltage 1 Block 0 to 4294967295 --- 1 F300 0Table B–10: MODBUS MEMORY MAP (Sheet 27 of 59)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT