B-46 L60 Line Phase Comparison System GE MultilinB.4 MEMORY MAPPING APPENDIX BB9AA1 Teleprotection Channel 1 Number of Lost Packets 0 to 65535 --- 1 F001 09AA2 Teleprotection Channel 2 Status 0 to 2 --- 1 F134 2 (n/a)9AA3 Teleprotection Channel 2 Number of Lost Packets 0 to 65535 --- 1 F001 09AA4 Teleprotection Network Status 0 to 2 --- 1 F134 2 (n/a)9AAF Teleprotection Channel 1 Input States 0 to 1 --- 1 F500 09AB0 Teleprotection Channel 2 Input States 0 to 1 --- 1 F500 09AC0 Teleprotection Input 1 States, 1 per register (16 items) 0 to 1 --- 1 F108 0 (Off)9AD0 Teleprotection Input 2 States, 1 per register (16 items) 0 to 1 --- 1 F108 0 (Off)Charge Current Compensation Settings (Read/Write Grouped Setting)9EF0 Charging Current Compensation Factor 0 to 1 --- 1 F102 0 (Disabled)9EF1 Charging Current Compensation Block 0 to 4294967295 --- 1 F300 09EF3 Charging Current Compensation Positive-Sequence Xc 0.100 to 65.535 kohms 0.001 F001 1009EF4 Charging Current Compensation Zero-Sequence Xc 0.100 to 65.535 kohms 0.001 F001 100Pilot Permissive Overreach Transfer Trip (POTT) Settings (Read/Write)A070 POTT Scheme Function 0 to 1 --- 1 F102 0 (Disabled)A071 POTT Permissive Echo 0 to 1 --- 1 F102 0 (Disabled)A072 POTT Rx Pickup Delay 0 to 65.535 s 0.001 F001 0A073 POTT Transient Block Pickup Delay 0 to 65.535 s 0.001 F001 20A074 POTT Transient Block Reset Delay 0 to 65.535 s 0.001 F001 90A075 POTT Echo Duration 0 to 65.535 s 0.001 F001 100A076 POTT Line End Open Pickup Delay 0 to 65.535 s 0.001 F001 50A077 POTT Seal In Delay 0 to 65.535 s 0.001 F001 400A078 POTT Ground Direction OC Forward 0 to 4294967295 --- 1 F300 0A07A POTT Rx 0 to 4294967295 --- 1 F300 0A07C POTT Echo Lockout 0 to 65.535 s 0.001 F001 250A07D POTT Target 0 to 2 --- 1 F109 0 (Self-reset)A07E Reserved 0 to 2 --- 1 F109 0 (Self-reset)VT Fuse Failure (Read/Write Setting) (4 modules)A09A VT Fuse Failure 1 Function 0 to 1 --- 1 F102 0 (Disabled)A09B VT Fuse Failure Neutral Wire Open 1 Function 0 to 1 --- 1 F102 0 (Disabled)A09C VT Fuse Failure Neutral Wire Open 1 3rd Harmonic Pickup 0 to 3 pu 0.001 F001 100A09D ...Repeated for module number 2A0A0 ...Repeated for module number 3A0A3 ...Repeated for module number 4VT Fuse Failure Actuals (Read Only) (4 modules)A0AC VT Fuse Failure 1 V0 3rd Harmonic 0 to 999999.999 V 0.001 F060 0A0AE ...Repeated for module number 2A0B0 ...Repeated for module number 3A0B2 ...Repeated for module number 4A0C0 Summator 1 Function 0 to 1 --- 1 F102 0 (Disabled)Selector Switch Actual Values (Read Only)A210 Selector Switch 1 Position 1 to 7 --- 1 F001 0A211 Selector Switch 2 Position 1 to 7 --- 1 F001 1Selector Switch Settings (Read/Write) (2 modules)A280 Selector 1 Function 0 to 1 --- 1 F102 0 (Disabled)A281 Selector 1 Range 1 to 7 --- 1 F001 7A282 Selector 1 Timeout 3 to 60 s 0.1 F001 50A283 Selector 1 Step Up 0 to 4294967295 --- 1 F300 0A285 Selector 1 Step Mode 0 to 1 --- 1 F083 0 (Time-out)A286 Selector 1 Acknowledge 0 to 4294967295 --- 1 F300 0A288 Selector 1 Bit0 0 to 4294967295 --- 1 F300 0A28A Selector 1 Bit1 0 to 4294967295 --- 1 F300 0A28C Selector 1 Bit2 0 to 4294967295 --- 1 F300 0A28E Selector 1 Bit Mode 0 to 1 --- 1 F083 0 (Time-out)Table B–10: MODBUS MEMORY MAP (Sheet 38 of 59)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT