B-34L90 Line Differential RelayGE Power ManagementB.4 MEMORY MAPPING APPENDIX BB9A1B ...Repeated for module number 149A1D ...Repeated for module number 159A1F ...Repeated for module number 16Setting Groups (Read/Write Setting)A000 Setting Group for Modbus Comm (0 means group 1) 0 to 7 --- 1 F001 0A001 Setting Groups Block 0 to 65535 --- 1 F300 0A002 FlexLogic Operands to Activate Grps 2 to 8 (7 items) 0 to 65535 --- 1 F300 0A009 Setting Group Function 0 to 1 --- 1 F102 0 (Disabled)A00A Setting Group Events 0 to 1 --- 1 F102 0 (Disabled)Setting Groups (Read Only)A00B Current Setting Group 0 to 7 --- 1 F001 0VT Fuse Failure (Read/Write Setting) (6 modules)A040 VT Fuse Failure Function 0 to 1 --- 1 F102 0 (Disabled)A041 ...Repeated for module number 2A042 ...Repeated for module number 3A043 ...Repeated for module number 4A044 ...Repeated for module number 5A045 ...Repeated for module number 6Pilot POTT (Read/Write Setting)A070 POTT Scheme Function 0 to 1 --- 1 F102 0 (Disabled)A071 POTT Permissive Echo 0 to 1 --- 1 F102 0 (Disabled)A072 POTT Rx Pickup Delay 0 to 65.535 s 0.001 F001 0A073 POTT Transient Block Pickup Delay 0 to 65.535 s 0.001 F001 20A074 POTT Transient Block Reset Delay 0 to 65.535 s 0.001 F001 90A075 POTT Echo Duration 0 to 65.535 s 0.001 F001 100A076 POTT Line End Open Pickup Delay 0 to 65.535 s 0.001 F001 50A077 POTT Seal In Delay 0 to 65.535 s 0.001 F001 400A078 POTT Ground Direction OC Forward 0 to 65535 --- 1 F300 0A079 POTT Rx 0 to 65535 --- 1 F300 0A07A POTT Echo Lockout 0 to 65.535 s 0.001 F001 250Digital Elements (Read/Write Setting) (16 modules)B000 Digital Element x Function 0 to 1 --- 1 F102 0 (Disabled)B001 Digital Element x Name --- --- --- F203 "Dig Element 1 "B015 Digital Element x Input 0 to 65535 --- 1 F300 0B016 Digital Element x Pickup Delay 0 to 999999.999 s 0.001 F003 0B018 Digital Element x Reset Delay 0 to 999999.999 s 0.001 F003 0B01A Digital Element x Block 0 to 65535 --- 1 F300 0B01B Digital Element x Target 0 to 2 --- 1 F109 0 (Self-reset)B01C Digital Element x Events 0 to 1 --- 1 F102 0 (Disabled)B01D Digital Element x Reserved (3 items) --- --- --- F001 0B020 ...Repeated for module number 2B040 ...Repeated for module number 3B060 ...Repeated for module number 4B080 ...Repeated for module number 5B0A0 ...Repeated for module number 6B0C0 ...Repeated for module number 7B0E0 ...Repeated for module number 8B100 ...Repeated for module number 9B120 ...Repeated for module number 10B140 ...Repeated for module number 11B160 ...Repeated for module number 12B180 ...Repeated for module number 13B1A0 ...Repeated for module number 14B1C0 ...Repeated for module number 15Table B–9: MODBUS MEMORY MAP (Sheet 26 of 38)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT