GCL-GCXOPENCLOSESTOPCALRUN SCROLL SETCLEARSetting Close DirectionSET CLOSE DIRFigure 2OPENCLOSESTOPCAL SETHIT CLOSE KEYOPENCLOSESTOPCAL SETDID DOOR CLOSE?Figure 3Figure 4OPENCLOSESTOPCALRUN SCROLLSCROLLSETCLEARFigure 5SCROLL KEYCALRUNCLOSESCROLLSCROLLSETCLEARCALRUNYES NOThe direction of motor rotation depends on mounting position. This setting isused to insure the door is closing and opening according to the input commands.1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.2) Press SCROLL until “SET CLOSE DIR” is displayed. Figure 2.SETCLEAR2) Press SET/CLEAR to begin the calibration procedure and advance tothe next screen. Figure 3.3 ) Briefly press the CLOSE key. (Pressing the Scroll key at this point will exitthis control function.)• The display will read “ DID DOOR CLOSE? “ Figure 44) Press SCROLL key (up or down) to toggle between YES and NO.Figure 5.• If YES is selected, no change to operator calibration is made. IfNO is selected — the POD will change the operator’s down direction.5) Press the SET/CLEAR key.6) Press CAL/RUN to return to run mode or, press SCROLL to shift toanother function.6.2SCROLLwww.geniecompany.com 08-12Counter Door Operator