GCL-GCXOPENCLOSESTOPCALRUN SCROLLSCROLLSETCLEAROPENCLOSESTOPCALRUN SCROLLSCROLLSETCLEARThe operators also include a run code memory that stores the last 10 run events.These codes are stored with or without power. Each time the operator runs or stops, itgenerates a code that it stores in this memory (Why the operator ran or stopped). Usedtogether with the error code memory, it becomes a powerful troubleshooting aid.The run code memory stores the last 10 codes in sequence. Once 10 codes are stored,the oldest code is erased to make room for the newest code. These codes are displayedin calibration mode. The display will flash the number of the run code and the 2-digitrun code followed by a description of the run code. Fig. 3 & 4.Run CodesRUN CODE 1 3CFigure 3HALT DOWN LIMITFigure 4Error Codes (continued)CALRUNSCROLLCRSETCLEARCALRUNTo view the error code memory:1) Press CAL/RUN to enter calibration mode.2) Press SCROLL until display reads “ERROR CODE 1 >”.• The display will begin flashing the error code number and 2-digiterror code followed by its description.• Reminder: Error code number 1 is the latest code generated.3) Press SET/CLEAR . The display will now read “ERROR CODE 2 > .”(This is the error code which was generated before error code 1.)4) Repeat step 3 until all 10 error codes have been displayed or move on tostep 5 when ready.5) Press CAL/RUN to return to run mode.NOTE: For all error codes see Appendix C, Sections 10.6 - 10.7.8.2www.geniecompany.com 08-12Counter Door Operator